BW40-04 Autonics Area Sensor

Available on order

$243.58 Excluding GST

For Bulk requirement, Kindly click on enquiry now button

 

Product Details:

Product Description
Brand Autonics
Model no BW40-04
Sensing type Through-beam type(direct beam)
Sensing distance 0.1 to 7m
Light source Infrared LED(850nm modulated)
Optical axis pitch 40mm
Number of optical axes 8
Sensing height/Total length 280/340mm
Power supply 12-24VDC  ±10%(ripple P-P: max. 10%)
Control output PNP open collector
Operation mode Light ON
Environment Ambient illumination Ambient light: Max. 10,000lx(receiver illumination)
Environment Ambient temperature -10 to 55℃, storage: -20 to 60℃
Connection type Cable connector type(Ø5, 300mm, M12)
Protection structure IP65
Approval CE
Environment Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Min. sensing target Opaque material of min. Ø50mm
Response time Max. 10ms
Material • Case: Aluminum, • Front cover, sensing part: Acrylic
Cable specification Ø5mm, 4-wire, 300mm, M12 connector
Weight Approx. 2.1kg(approx. 1.4kg)

Above specifications mentioned are for quick reference only. Actual technical details has to be obtained from below catalog.

Autonics TK4S-B4CN Temperature Controller

Description

BW40-04 Autonics  Area Sensor

Features

  1. Long sensing distance up to 7M
  2. 22 types of products (Optical axis : 20/4Omm. Sensing height 1 20-94Omm)
  3. Increased sensing stability by minimizing the non sensing area
  4. Easy identification of the side, front and Long distance with
    high luminance twin operation indicators
  5. Includes self-diagnosis function, mutual interference provention
    function, external diagnosis function.
  6. Polished design & slim size(W28.6× H22.6x Lmm)
  7. IP65 rated waterproof structure (IEC standard)

Functions of Autonics Area Sensor BW40-04

Stop transmission function(External diagnosis function)

The transmission will be stopped and a yellow LED is flashed if supplying OV to test input on the emitter. It is for checking the malfunction of the sensors during TEST input on the emitter is OV. (Control output of the receiver is OFF as it becomes light cut off when the transmission is stopped.)

Self-diagnosis function

Control output will be OFF and the operating indicator is ON when a malfunction is checked by self-diagnosis regularly in normal operation.

Diagnosis items

Emitter: 1) Break of the light emitting element
2)Break of light emitting circuit
3)Malfunction of MASTER/SLAVE line (Operation in MASTER)

Receiver: 1) Break of the light receiving circuit
2) Break of the output circuit

3) Overcurrent at output part

4)Synchronous line malfunction

5)Extraneous light received

 