Description
AA004-000(C/Y) City Technology Oxygen Sensor
C/Y Metal Can Oxygen O2 gas sensor, 0-25% vol. O2
Measuring Range: 0 – 25% vol. O2. Maximum Overload: 30% vol. O2
General purpose Metal Can sensor ideal for industrial safety, available for Fixed and Portable systems
Part number : AA004-000
Linearity
The output signal of an Oxygen C/Y follows the relationship:
S=Klog 1/(1-C)
where:
S = Output signal;
C= Fractional oxygen concentration;
K = a constant for the sensor.
For most applications the deviation from a linear response will be insignificant, and no compensation needed.
For example, the graph oppisite shows the output of a sensor calibrated in air (20.9% O ). In this 2 case the maximum error in the 0-25%range is ≈ 0.5% at around 10%O2.